Planet Technology SGSD-1022P Switch User Manual


 
User’s Manual of SGSD-1022 / SGSD-1022P
SGSW-2840 / SGSW-2840P
71
4.2.8 Log
The switch allows you to control the logging of error messages, including the type of events that are recorded in switch memory,
logging to a remote System Log (syslog) server, and displays a list of recent event messages. This section has the following
options:
System Logs
Sends error messages to a logging process
Remote Logs
Configures the logging of messages to a remote logging process
SMTP
Sends an SMTP client message to a participating server.
Logs
Stores and displays error messages
4.2.8.1 System Log Configuration
The system can be configured to send debug and error messages to a logging process. This logging process controls the type
of error messages that are stored in switch memory or sent to a remote syslog server.
The system allows you to enable or disable event logging, and specify which levels are logged to RAM or flash memory.
Severe error messages that are logged to flash memory are permanently stored in the switch to assist in troubleshooting
network problems. Up to 4096 log entries can be stored in the flash memory, with the oldest entries being overwritten first when
the available log memory (256 kilobytes) has been exceeded.
The System Logs page allows you to configure and limit system messages that are logged to flash or RAM memory. The default
is for event levels 0 to 3 to be logged to flash and levels 0 to 6 to be logged to RAM.
The following table lists the event levels of the Managed Switch:
Level Severity Name Description
7
Debug
Debugging messages
6
Informational
Informational messages only
5
Notice
Normal but significant condition, such as cold start
4
Warning
Warning conditions (e.g., return false, unexpected return)
3
Error
Error conditions (e.g., invalid input, default used)
2
Critical
Critical conditions (e.g., memory allocation, or free memory
error - resource exhausted)
1
Alert
Immediate action needed
0
Emergency