Chapter 4 Maintenance Schedules
92
Tech Service Replacement Schedule
Each time a service technician completes a level of preventive
maintenance, he or she must reset the service level page count by
selecting the Technician Service option on the Maintenance menu.
This removes the maintenance error message.
The following actions should be performed by a service technician
after the specified number of letter size pages (4% coverage) have
been printed.
Item Part #
Frequency
(Pages)
Action
Service
Level
Main charger
705741-001 300,000 Replace D
Precharger
705742-001 300,000 Replace D
Transfer charger
705742-001 300,000 Replace D
Smoke filter
703540-001 300,000 Replace D
Flash power supply filter
n/a 300,000 Clean D
LED air filter
703543-001 600,000 Clean E
Lamp housing filter
202838-001 600,000 Clean E
Cleaning unit
705740-001 600,000
See Note 1
Replace E
Transporting belt-3
703531-035 600,000 Replace E
Xenon lamp
703541-001 900,000 Replace F
Main charger
705741-001 1,200,000 Replace G
Precharger
705742-001 1,200,000 Replace G
Transfer charger
705743-001 1,200,000 Replace G
Cleaning unit
705740-001 1,200,000
See Note 1
Replace G
Lamp housing filter
202838-001 2,400,000 Replace H