RAD Data comm ASMI-450 Modem User Manual


 
ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual 4-13
2. The password entry screen appears, e.g.:
NEW PASSWORD (4 to 8 CHARS) =
CURRENT PASSWORD = 'password'
where 'password' is the current password.
3. Type the required password. Carefully check that the specified password has been
indeed typed in, and then press <CR>. The ASMi-450 will display the TIME and
DATE fields, followed by the ASMi-450 prompt.
Note
Before entering a new password, make sure that the PSWD section of the
ASMi-450 internal switch S1 is not set to ON, because in such a case the default
password (ASMI) is enforced.
DEF SP-----------------------------------------------------------------------------------------
Purpose
Assign values to control port parameters. See Section 3-5 for parameter description and
allowable ranges, and Section 3-7 for practical selection recommendations.
Format
DEF SP
Use
1. Type
DEF SP<CR>
2. The first page of the control port parameters data form is displayed. A typical form is
shown below. The form presents the current parameter values as defaults.
SPEED DATA PARITY INTERFACE CTS DCD_DEL DSR
AUTO 8 NO DCE =RTS 0_MSEC ON
3. Change the parameter values as follows:
Bring the cursor to the beginning of the first field to be changed by pressing the
space bar.
To change the selected field, press F or B to scroll among the available
selections.
When the desired selection is displayed, press the space bar to move to the next
field.
4. When done, press <CR> to display the next page of control port parameters. A typical
form is shown below.
POP_ALM PWD LOG_OFF AUXILIARY DEVICE
NO NO NO TERMINAL