RAD Data comm ASMI-450 Modem User Manual


 
ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual 4-15
DEF SYS---------------------------------------------------------------------------------------
Pur
p
ose
Assign values to system parameters.
Format
DEF SYS
Use
1. Type
DEF SYS<CR>
2. The system parameters data form is displayed. A typical form for an ASMi-450/1152
with Ethernet interface is shown below. The form presents the current parameter
values as defaults. For ASMi-450 with serial data port, the ETHERNET_MODE and
BRIDGING fields always show N/A.
CLK_MASTER ACTIVE_TS ETHERNET_MODE BRIDGING
EXT 18 HALF_DUP FILTER
See Section 3-4 for a description of the various parameters, and Section 3-7 for practical
selection recommendations.
3. Change the parameter values as follows:
Bring the cursor to the beginning of the first field to be changed by pressing the
space bar.
To change the selected field, press F or B to scroll among the available
selections.
When the desired selection is displayed, press the space bar to move to the next
field.
4. After the desired parameter values are selected, press <CR> to end. The ASMi-450
will display the TIME and DATE fields, followed by the ASMi-450 prompt.
DEF TERM ------------------------------------------------------------------------------------
Pur
p
ose
Define the control sequences to be sent to the supervision terminal to perform the
following terminal control functions:
Clear screen.
Move cursor to screen home position.
Move cursor to the right by one position.
This command is similar to the F command (see F section below), except that it also
enables you to specify a terminal type and the ASMi-450 will automatically configure
itself for using the corresponding control sequences. The terminal types supported by
this command are: VT-52, VT-100, TV-920, FREEDOM-100, FREEDOM-110,
FREEDOM-220, and terminals compatible with one of them.
The codes used by the supported terminals are listed in the following chart: