RAD Data comm ASMI-450 Modem User Manual


 
ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual 4-17
Table 4-B. Control Terminal Alarm Messages
Alarm No. Alarm Syntax Meaning State Time
1 LOCAL DB
CHECKSUM ERROR
The data base currently stored in the non-
volatile memory of the local ASMi-450 is
corrupted. Message can appear only upon
power-up
[ON] hh:mm:ss
2 LOCAL ALARM
BUFFER OVERFLOW
The alarm buffer of the local ASMi-450 is
full, and new alarms overwrite the older
alarms
[ON] [OFF] hh:mm:ss
3 LOCAL SELF TEST
ERROR
A fault has been detected in the local
ASMi-450 during the power-up self-test
[ON] hh:mm:ss
4 LOCAL HARDWARE
FAILURE
A hardware fault has been detected in the
local ASMi-450
[ON] hh:mm:ss
5 LOCAL PSWRD
SWITCH IS ON
Section PSWD of switch S1 of the local
ASMi-450 is set to ON
[ON] hh:mm:ss
6 LOCAL SP-PAR
SWITCH IS ON
Section DEF SP of switch S1 of the local
ASMi-450 is set to ON
[ON] hh:mm:ss
7 LOCAL DB-INIT
SWITCH IS ON
Section DB INIT of switch S1 of the local
ASMi-450 is set to ON
[ON] hh:mm:ss
8 LOCAL REAL TIME
CLOCK BATTERY
FAILURE
The battery that powers the local
ASMi-450 internal real-time clock when
ASMi-450 is not powered has failed
[ON] hh:mm:ss
9 LOCAL REVERSE
POLARITY
Reversed loop polarity has been detected
by the local ASMi-450
[ON] hh:mm:ss
10 LOCAL SIGNAL LOSS Loss of HDSL line input signal at the local
ASMi-450
[ON] [OFF] hh:mm:ss
11 LOCAL SYNC LOSS The local ASMi-450 lost synchronization
to the HDSL line signal
[ON] [OFF] hh:mm:ss
12 LOCAL LOW QUALITY
ALARM
The CRC-6 error rate detected on the
incoming HDSL signal exceeds 10
-7
[ON] hh:mm:ss
13 LOCAL TRANSMIT
SLIP
A slip has been detected on the local
transmit path
[ON] hh:mm:ss
14 LOCAL RECEIVE SLIP A slip has been detected on the local
receive path
[ON] hh:mm:ss
15 LAN NOT CONNECTED No data is received from the user's port
(for ASMi-450 version with serial data
port).
or
The Ethernet interface is not connected to
an operating LAN (at least one station
must be active on the LAN)
[ON] [OFF] hh:mm:ss