Renesas M3062PT-EPB Switch User Manual


 
( 24 / 80 )
2.4 When Using the Emulator for the First Time
2.4.1 Downloading Firmware
If you have purchased this emulation probe newly, you need to download the firmware. The
download procedure is given in Figure 2.3.
Before downloading the firmware, check that emulator debugger M3T-PD30F is installed to your
host machine and the PC7501 is connected to the host machine. For more details, see each user's
manual of the emulator debugger M3T-PD30F and the PC7501.
Figure 2.3 Firmware download procedure
2.4.2 Self-check
Execute the self-check after downloading the firmware to check that the emulation probe operates
properly. Figure 2.4 shows the self-check procedure.
See "3.5 Connecting the PC7501"
(page 33).
See "3.1 Selecting Clock Supply"
(page 26).
See "4.2 Downloading Firmware"
(page 48).
Figure 2.4 Self-check procedure
See "4.3 Self-check" (page 49).
Install oscillator circuit board OSC-3 (16 MHz)
included with this product to the PC7501
Connect this product and the PC7501.
Within 2 seconds of turning the power ON,
press the system reset switch of the PC7501
and check it is in maintenance mode.
Startup emulator debugger M3T-PD30F
and download the firmware.
Quit the emulator debugger
and shut down the PC7501.
Within 2 seconds of turning the power ON,
press the system reset switch of the PC7501
and check it is in maintenance mode.
After about 30 seconds, check that the self-check is
terminated normally and shut down the PC7501.
Press the system reset switch of the PC7501
to start the self-check.