Renesas M3062PT-EPB Switch User Manual


 
( 37 / 80 )
3.6.3 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 1)
Here following is a procedure of connecting to a 100-pin 0.65-mm-pitch foot pattern on the target
system using the M3T-DIRECT100S (not included). For details on the M3T-100LCC-DMS (not
included) and M3T-DIRECT100S, refer to each user's manual.
(1) Attach the M3T-DIRECT100S to the target system.
(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S.
(3) Attach the CN2 side of the M30800T-PTC to the J4 side of the M3062PT-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
Figure 3.14 Connecting to a 100-pin 0.65-mm-pitch foot pattern (Part 1)
CAUTION
Notes on Connecting the Target System:
•Take care not to attach a converter board in a wrong direction. It may cause a fatal
damage to the emulator and targets system.
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
The connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed
for only 20 insertion/removal iterations.
M3062PT-EPB
M30800T-PTC
100-pin 0.65-mm-pitch (100P6S) foot pattern
M3T-DIRECT100S (not included)
M3T-100LCC-DMS (not included)
Target board
CN2 side
M3T-FLX160-EPB
No. 1 pin
(1)
(2)
(4)
(3)