Ricoh 270 All in One Printer User Manual


 
Replacing Photo Conductor Unit (PCU)
93
3
Replacing Photo Conductor Unit (PCU)
When 'Replace photocondoctor unit' appears on the panel display, it is time to
replace the photo couductor unit.
R
WARNING:
Note
Do not tilt used PCU after removing it from the machine. If you do, toner
might fall out.
Do not hold the developer cartridge when removing the used PCU from your
machine. If you do, the cartridge might come unlocked and fall.
Do not touch the photo couductor. If you do, abnormal copies might be made.
Before you remove the used PCU from the machine, wait until the machine
has completely stopped and is making no sound. Failure to take this precau-
tion could result in a fault.
If there are misfeeds, remove the misfed paper before removing the used
PCU.
Be sure to remove the sealing tape before setting the new PCU. Leaving it on
could cause a fault.
After replacing the PCU, the machine will take about 1 minutes to initialize.
During this period, do not open the front cover or turn off the main switch. If
you do, a fault might occur.
A If the duplex unit is installed, open the duplex unit by pushing the catch
upwards.
Do not incinerate the photoconductor unit. Toner dust might ignite
when exposed to an open flame. Dispose of the used photoconductor
unit in accordance with local regulations for plastics.