Rose electronic KVM SWITCH WITH ON-SCREEN DISPLAY Switch User Manual


 
ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL
11
* 4 units can be cascaded using a 4-port master/16 using a 16-port master
Figure 4. Cascading units
Slave unit installation
To properly install the slave units, follow the below steps.
(See the Configure System menu section for detailed instructions)
1. Connect the KVM stations keyboard, monitor, and mouse to the
master units Monitor/Keyboard/Mouse connector using the
appropriate KVM cable.
2. Connect CPU port #1 on the master unit to the KVM connector
on Slave #1 using a DB25 to DB25 expansion cable.
(Rose Electronics part number CAB-CXVSMMnnn)
3. Connect the next sequential CPU port on the master unit to the
KVM connector on the next sequential Slave unit.
4. Connect the remaining Slave units to the master unit.
5. When all slave units are connected, call up the UltraView Pro’s
“Main configuration” menu by pressing and releasing the left
control <Ctrl> key, then the F12 key. (See Figure 5).
6. Using the up/down arrow keys, select (highlight) “Configure
system” and press enter. The “Configure system” menu will
display. (See Figure 6)
7. Using the up/down arrow keys, select “Maximum computers”
and press enter. Enter the total possible number of computers
in the system and press enter.
MASTER
CPUs 1
-
8
CPUs 9
-
16
CPUs 17-22
KVM station
Up to 8 UltraView Pro
SLAVE #2 Slaves can be connected* SLAVE #1