Rose electronic KVM SWITCH WITH ON-SCREEN DISPLAY Switch User Manual


 
32
ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL
If any of these errors occur, check the RS232 cable, the connectors,
and the adapter. Make sure they are in good working order. Verify
the communication program is configured correctly. Enter “Y” to try
upgrading the flash again. If programming is unsuccessful, the unit
should be serviced.
Method 2 – Using the front panel switches with a file copy.
1. Press both the - and + switches on the front panel and power
up the UltraView Pro. The UltraView Pro is ready to accept the
upgrade file. LED 1 will light indicating the unit is set at 9600
baud. To use 57600 baud, press the + switch, LED 4 will light.
Copy the file to the unit. While the file is being copied LED 1 or
4 will flash. Once the file is copied, LED 2 will light.
2. Press and release the + switch, LED 2 flashes off for a brief
instant. The flash is now being programmed and verified. LED 3
now lights.
3. Press and release the + switch, LED 3 flashes off for a brief
instant. The new firmware is now run and diagnostic information
is sent to the on-screen display. Observe the new revision
number matches that of the file. LED 4 now lights.
4. Press and release the + switch. LED 1 now lights. The box is
now operational and port 1 is selected or the login box is
waiting for its password. The flash loading procedure is
complete.
Figure 11. Power-on diagnostic screen
Welcome to UltraView Pro
Power on diagnostics
Kernel revision - - - - - - P3
Hardware type - - - - - - PC
Kernel checksum - - - - GOOD
Static ram - - - - - - - - - GOOD
Com interface - - - - - - GOOD
Program revision - - - - UP18
Program checksum - - GOOD
Total ports found - - - - 08
Config checksum - - - - GOOD
PC keyboard detected
PS/2 mouse detected