8
9. When asked Are You Sure (Y/N)?, press Y.
10. Press Ctrl+E to exit the BIOS.
11. When asked Are you sure to exit (Y/N)?, press Y to
exit.
Note: If during restart the RAID BIOS reports an
incomplete Mirror set, disregard the message,
continue booting, and let the Mirror rebuild.
Creating a SPARE Drive
When a hard drive failure occurs in a mirror set, the auto-
rebuild feature enables a drive designated as SPARE to
become the new member of the mirror set.
1. During boot press Ctrl+S or F4 to enter the RAID
BIOS.
2. Select Create RAID Set press Enter.
3. Select SPARE DRIVE, then press Enter.
4. Select the single hard drive then press Enter.
5. When asked Are You Sure (Y/N)?, press Y to confirm.
6. Press Ctrl+E to exit.
7. When asked Are you sure to exit (Y/N)?, press Y to
exit.
The SPARE drive will not be seen by Windows, however,
it remains in the background waiting to rebuild the
mirror in the event of a hard drive failure.
Rebuilding a Failed Mirror Set
When a failure to one member occurs, you will be notified
either by the RAID BIOS during boot or by the SATA
Raid GUI while in Windows. The steps below will guide
you in rebuilding a failed mirror set.
1. Replace the failed drive(s) with one of equal or
greater capacity, then start the computer.