Sony DVS-V6464B/V6464M Network Router User Manual


 
5-50
ROUTING SWITCHER SYSTEM (E)
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only)
MONITOR SYSTEM SETUP MENU BKS-R1607 V1.00 STATION NUMBER 3
SET PANEL TABLE(SOURCE) CONTROL DESTINATION = OUT001
01 KEY=IN001 02 KEY=IN002 03 KEY=IN003 04 KEY=IN004
05 KEY=IN005 06 KEY=IN006 07 KEY=IN007 08 KEY=IN008
09 KEY=....... 10 KEY=....... 11 KEY=....... 12 KEY=.......
13 KEY=....... 14 KEY=....... 15 KEY=....... 16 KEY=.......
17 KEY=IN009 18 KEY=IN010 19 KEY=IN011 20 KEY=IN012
21 KEY=IN013 22 KEY=IN014 23 KEY=IN015 24 KEY=IN016
25 KEY=....... 26 KEY=....... 27 KEY=....... 28 KEY=.......
29 KEY=....... 30 KEY=....... 31 KEY=....... 32 KEY=.......
SET PANEL TABLE(DESTINATION)
01 KEY=....... 02 KEY=....... 03 KEY=....... 04 KEY=.......
05 KEY=....... 06 KEY=....... 07 KEY=....... 08 KEY=.......
09 KEY=OUT001 10 KEY=OUT002 11 KEY=OUT003 12 KEY=OUT004
13 KEY=OUT005 14 KEY=OUT006 15 KEY=OUT007 16 KEY=OUT008
17 KEY=....... 18 KEY=....... 19 KEY=....... 20 KEY=.......
21 KEY=....... 22 KEY=....... 23 KEY=....... 24 KEY=.......
25 KEY=OUT009 26 KEY=OUT010 27 KEY=OUT011 28 KEY=OUT012
29 KEY=OUT013 30 KEY=OUT014 31 KEY=OUT015 32 KEY=OUT016
0=IN 1=OUT 2=.... 3=.... 4=.... 5=.... 6=.... 7=....
8=.... 9=.... A=.... B=.... C=.... D=.... E=.... F=....
Ctrl-E:MENU Ctrl-D:RETURN Ctrl-N:Type + Num
N: SET PANEL TABLE (BKS-R1607/R1608/R3204/R3205/R3209/R3210) <MONITOR MENU>
Purpose
This menu is used to assign source/destination name to
each source/destination selection button.
In the monitor mode, the button color of the remote control
unit will be green for both source and destination.
Setting Procedure
1. Select menu item [N].
2. Select a button number using the cursor.
3. When [Enter] is pressed, the name can be typed.
To delete the registration, press [Enter] before
inputting the name.
4. a) When [J : NAME STYLE (Type + Num)] is
selected in the primary station menu, input the
type name (between 0 and F) and the number for
the source and destination.
b) Each time [Ctrl] _ [N] is pressed when [J :
NAME STYLE (DESCRIP. NAME)] is selected
in the primary station menu, the following input
modes will be switched alternately.
Description name input mode :
When “Ctrl N: Type + Num” is displayed on the
screen, it means that the name mode will be changed
to “Type + Number” by pressing [Ctrl] _ [N].
Inputs the Description name from the first to seventh
characters with alphabet and numerical keys.
“Type + Number” name input mode :
Same as a)
n
If the Description name has been set for the input/output
number the display of Description has priority to the
display of “Type + Number” even if the “Type + Number”
name is input.
5. When [Enter] is pressed, the source name is set.
6. When [Ctrl] _ [E] is pressed, the screen will return to
the menu screen of the secondary station on the
monitor S-BUS.
When [Ctrl] _ [Z] is pressed, the screen will return to
the menu screen of the primary station on the monitor
S-BUS.
When [Ctrl] _ [D] is pressed, the screen will return to
the menu screen of the primary station on the standard
S-BUS.
Example of Setting Screen
m
1. Set the table data of BKS-R3204/R3205/R3206 by
eight buttons previously in the menu item [Z : SET
____ PANEL STATUS]. If “KEY = ____” is
displayed on the key number position, the name can
not be input.
2. Be sure to set either source or destination on the
respective buttons (keys) when setting the BKS-
R1607/R1608/R3209/R3210.
If both source and destination are set to the same
button (key), it will cause malfunction.
3. When setting description names to the source/destina-
tion buttons, select a name from the description name
group sent to the remote control unit.
If other names are input, these will not be set even if
the [Enter] button is pressed.
In such cases, transfer the group including the desired
description name from the primary station.