Control Codes PcOS Series 150 Programmer's Guide
Summary by Function
Page 88 Rev G 12/14/99
Bar codes
[ESC] b <n> ...
[ETX]
1BH,62H &%25 {n=0}
&%39 {n=1}
&%12 {n=2}
&%UP {n=3}
&%EA {n=4}
&%EA {n=5}
&%EA {n=6}
&%93 {n=7}
&%HB {n=10}
Print bar codes.
n=0 Interleave 2 of 5
n=1 Code 39
n=2 Code 128
n=3 UPC A
n=4 EAN-13
n=5 UPC E
n=6 EAN-8
n=7 Code 93
n=10 Hollerith
48
[ESC] [EM] B
<n>
1BH,19H,
42H
&%BH <m
1
> Set bar code height.
n=0 restore defaults
n=1-9 number of passes
(0.11” per pass)
50
[ESC] [EM] J
<n>
1BH,19H,
4AH
&%BJ <m
1
><m
2
> Set bar code justification. 50
Validation control
[ESC] [DC1] 1BH,11H &%VO Open for validation. 52
[ESC] [DC3] 1BH,13H &%VC Close for validation. 52
[ESC] [DC4] 1BH,14H &%VS Select validation mode with auto
form sense.
52
[ESC] [EM] C
<n>
1BH,19H,
43H
&%ZC <m
1
><m
2
> Set validation clamp delay. 53
[ESC] [EM] V
<n>
1BH,19H,
56H
&%ZV <m
1
><m
2
> Set validation time-out. 53
Miscellaneous
[ENQ] <n> 05H Set inquire status.
(Refer to command descriptions.)
62
[CAN] 18H &%RP Clear print buffer. 55
[ESC] 8 1BH,38H &%PF Disable paper error sensing. 51
[ESC] 9 1BH,39H &%PO Enable paper error sensing. 51
[ESC] < 1BH,3CH &%PT Set print suppress and pass
through.
57
[ESC] q<n> 1BH,71H None Set query marker. 56
[ESC] v 1BH,76H &%FC Cut Activate cutter. 58
[ESC] w <n> 1BH,77H None Enable dynamic response. 58
[ESC] x <n> 1BH,78H &%D1 {n=1}
&%D2 {n=2}
Open cash drawer.
n=1
n=2
55
Diagnostics
[ESC] y <n> 1BH,79H &%Y0 - 7 Control diagnostics and extended
features.
(See descriptions on page 57.)
57
[ESC] ~ <n> 1BH,7EH Set diagnostics commands enabled
by [ESC]y<8>. (See command
description for <n>.)
68