Star Micronics TSP1000 Printer User Manual


 
Notices 11-3
<Preparing Power on the User Side>
Be careful of the following points when using your own power unit, instead of using the optional power unit
(PS60L-24A).
• Power supply must be a minimum of DC 24 V ±10%; Min. 2.0 A.
(Select one with a current capacity that handles printing rates when actually used.)
• Take measures for the power supply to meet user side static electrical tolerance and AC noise tolerance values, by
considering the noise in the location where the printer will be setup.
* AC Line Noise Tolerance Supplement
AC line noise testing should have the following conditions.
• Noise Pulse Width: 100 ns
• Noise Shape: Rectangular Shape (Power Synch)
• Noise Pulse Infusion Angle: 90° (+) and 270° (-)
TSP1000 Series Product Specifications 11-2