Sun Microsystems 5602 Switch User Manual


 
4 – Managing Switches
Displaying Switch Information
59097-01 A 4-11
0
FDMI Enable Fabric Device Management Interface status. If enabled,
device information can be obtained, managed, and saved
through the fabric using Name Service Management
Server functions. SANsurfer Switch Manager will report
any and all FDMI information reported by the entry switch,
if FDMI is enabled on the entry switch. Refer to
”Displaying Detailed Device Information” on page 3-35 for
information about displaying FDMI information.
Number of Donor Groups Total number of donor port groups. A donor group is a set
of (1-Gbps/2-Gbps only) ports on a switch that can donate
buffer credits to each other.
Embedded GUI SANsurfer Switch Manager web applet status. Enables or
disables the web applet on the switch.
Inactivity Timeout Number of minutes the switch waits before terminating an
idle command line interface session. Zero (0) disables the
time out threshold.
GUI Mgmt Enabled Switch management application status. If disabled, the
switch cannot be managed using the application.
Telnet Enabled Telnet client status
SSH Enabled Secure Shell status. If enabled, an encrypted data path is
provided for command line interface sessions.
SSL Enabled Secure Sockets Layer status. If enabled, encryption for
switch management application and CIM sessions is
provided.
CIM Enabled Common Information Model status. The CIM agent is
based on the SNIA Storage Management Initiative
Specification (SMI-S), which is the standard for SAN
management in a heterogeneous environment.
FTP Enabled FTP status
Management Server
Enabled
Management server status.
Table 4-2. Switch Data Window Entries (Continued)
Entry Description