5 - 8 DS6707 Digital Imager Scanner Product Reference Guide
Gain / Exposure Priority for Snapshot Mode (continued)
Snapshot Mode Timeout
Parameter # F0h, 43h
This parameter sets the amount of time the digital imager scanner remains in Snapshot Mode. The digital
imager scanner exits Snapshot Mode when you pull the trigger, or when the Snapshot Mode Timeout elapses.
To set this timeout value, scan the bar code below followed by a bar code from Appendix D, Numeric Bar
Codes. The default value is 0 which represents 30 seconds; values increment by 30. For example, 1 = 60
seconds, 2 = 90 seconds, etc.
Low Gain Priority
(0)
Low Exposure Priority
(1)
* Autodetect
(2)
Snapshot Mode Timeout