4. Getting started
4.1. Initial Configuration
The TANDBERG Gatekeeper requires some configuration before it can be used. This must be done using
a PC connected to the serial port (Data 1) or by connecting to the system's default IP address:
192.168.0.100.
The IP address, subnet mask and gateway must be configured before use. The Gatekeeper has to be
configured with a static IP address. Consult your network administrator for information on which
addresses to use.
To set the initial configuration:
1. Connect the supplied null-modem RS-232 cable from Data 1 to a PC running a terminal program.
2. Start a terminal program and configure it to use the serial port with baud rate 115200, 8 data
bits, no parity, 1 stop bit, no flow control.
3. Power on the unit if it is not already on.
You should see the unit display start up information.
After approximately 2 minutes you will get a login prompt:
(none) login: admin
Password:
4. Enter the username admin and your password. The default password is TANDBERG.
You will be prompted if you want to run the install wizard:
Run install wizard [n]: y
5. Type y and press Enter.
6. Specify the following:
a. The password you want to use for your system. See Administrator Account (section 4.2.4)
for account details.
b. The IP address of the system.
c. The IP subnet mask of the system.
d. The IP default gateway of the system.
e. The Ethernet speed.
f. The local zone prefix, if any, you want to use for the zone controlled by this system. (You
should use a local zone prefix if you have a structured dial plan using E.164 aliases. See
Neighboring and dial plans (section 4.6.1) for more information.
g. Whether you want to use SSH to administer the system.
h. Whether you want to use Telnet to administer the system.
7. You will be prompted to log in again. You should see a welcome message like this:
Welcome to
TANDBERG Gatekeeper Release N5.1
SW Release Date: 2006-11-20
OK
8. Login with the username admin and your password.