TANDBERG Gatekeeper User Guide
Page 78 of 105
16.2.10. NTP
xconfiguration NTP Address: <IPAddress>
Sets the IP address of the NTP server to be used when synchronizing system time.
Accurate timestamps play an important part in authentication, helping to guard against replay attacks.
16.2.11. Option Key
xConfiguration Option [1..64] Key: <optionkey>
Specifies the option key of your software option.
An Option Key/software option is added to the system in order to add extra functionality, such as
increasing the system's capacity. Contact your TANDBERG representative for further information.
You must restart the system for changes to take effect.
Note: The command xstatus SystemUnit Software Configuration can be used to
discover the existing options.
16.2.12. Pipes
xconfiguration Pipes Pipe [1..100] Bandwidth Total Limit: <1..100000000>
Bandwidth associated with a pipe, keyed by index.
xconfiguration Pipes Pipe [1..100] Bandwidth Total Mode:
<None/Limited/Unlimited>
Whether or not a given pipe is enforcing total bandwidth restrictions. None corresponds to no bandwidth
available.
xconfiguration Pipes Pipe [1..100] Bandwidth PerCall Limit:
<1..100000000>
Per call bandwidth of a pipe.
xconfiguration Pipes Pipe [1..100] Bandwidth PerCall Mode:
<None/Limited/Unlimited>
Whether or not a given pipe is enforcing per-call bandwidth restrictions. None corresponds to no
bandwidth available.
xconfiguration Pipes Pipe [1..100] Name: <pipename>
Name for a pipe.
16.2.13. Services
xConfiguration Services CallTransfer Mode: <On/Off>
Controls whether or not third party call transfer is enabled. The Gatekeeper must also be operating in
call routed mode.