- 210 -
(6) CODE128
[Transfer code]
– – 2 3 4 5 6 7
0 NUL DLE SP 0 @ P ` p
1 SOH DC1 ! 1 A Q a q
2 STX DC2 " 2 B R b r
3 ETX DC3 # 3 C S c s
4 EOT DC4 $ 4 D T d t
5 ENQ NAK % 5 E U e u
6 ACK SYN & 6 F V f v
7 BEL ETB ' 7 G W g w
8 BS CAN ( 8 H X h x
9 HT EM ) 9 I Y i y
A LF SUB
*
: J Z j z
B VT ESC + ; K [ k {
C FF FS , < L \ l |
D CR GS – = M ] m }
E SO RS . > N ^ n ~
F SI US / ? O _ o
How to transmit control code data:
NUL (00H) → >@ (3EH, 40H)
SOH (01H) → >A (3EH, 41H)
STX (02H) → >B (3EH, 42H)
to
GS (1DH) → >] (3EH, 5DH)
RS (1EH) → > ^ (3EH, 5EH)
US (1FH) → >_ (3EH, 5FH)
How to transmit special codes:
Value
30 (Character >) → >0
95 → >1
96 → >2
97 → >3
98 → >4
99 → >5
100 → >6
101 → >7
102 → >8
Designation of start code:
START (CODE A) → >7
START (CODE B) → >6
START (CODE C) → >5
[Drawing code]
Value Code Table