- 45 -
Notes
(1) The check digit attach, increment/decrement, and zero suppress processes are
performed according to the following priority. If any of the conditions is improper,
no drawing will take place.
For example, the zero(s) is replaced by a space(s) as a result of zero
suppression but the modulus 10 designated to be attached cannot be
calculated.
Increment/decrement > zero suppression > attachment of check digit
(2) Up to 32 fields for which incrementing/decrementing has been designated can be
drawn. If the total of bit map font, outline font or bar code increment/decrement
fields exceeds 32, drawing will take place without incrementing/decrementing any
excessive field. The field to be incremented or decremented is incremented or
decremented until the Image Buffer Clear Command ([ESC] C) is transmitted.
[Example]
1) Format Command (Increment character string No. 001 (+1))
2) Format Command (No incrementing for character string No. 002)
3) Format Command (Increment character string No. 003 (+2))
4) Image Buffer Clear Command
5) Data Command (Character string No. 001 “0001”)
6) Data Command (Character string No. 002 “AB-”)
7) Data Command (Character string No. 003 “0100”)
8) Issue Command (2 labels)
9) Issue Command (1 label)
10) Image Buffer Clear Command
11) Data Command (Character string No. 002 “00000”)
12) Issue Command (1 label)
0001
AB - 0100
0002
AB - 0102
0003
AB - 0104
00000