Toshiba B-SV4D-GS Barcode Reader User Manual


 
- 46 -
(3) The Bit Map Font Format Command may be connected to the Outline Font Format
Command when transmitted.
[ESC] P C001; 0100, 0150, 1, 1, A, 00, B [LF]
C002; 0350, 0180, 1, 1, A, 00, B [LF]
C005; 0200, 0300, 25, 2, C, +05, 00, B, +0000000001 [LF]
V01; 0500, 0400, 0100, 0100, A, 00, B [LF] [NUL]
(4) When the drawing data is changed per label issue during printing, the field of the
drawing data for the previous label is automatically cleared using the character
string number, then the next drawing data is printed. Therefore, the character
string number which differs according to the drawing fields should be designated.
Since the automatic field clear is not performed between the Clear Command
([ESC] C) and Issue Command ([ESC] XS), the fixed data may be drawn using the
same character string number. In this case, the Format Command and Data
Command should be sent alternately. (After the Issue Command is sent, the fields
with the same character string number are automatically cleared until the Clear
Command is sent.)
(5) The link field designation is cleared by omitting the link field designation using the
same character string No. and reformatting data.
The link field designation can be also cleared by the Image Buffer Clear
Command.
(6) A print data string and link field No. cannot be programmed at the same time.
(7) The same character string number cannot be programmed more than once in one
format (one page).
Refer to Bit Map Font Data Command ([ESC] RC)
Outline Font Format Command ([ESC] PV)
Bar Code Format Command ([ESC] XB)