Ultimate Technology 600 POS Mouse User Manual


 
Series 600 POS Keyboard 15
Table 2. Local Mode Programming Instructions
* = Default Settings
Function Code(s)
Operation Normal Indication Remarks
02
Code Primary Key
Functions to
Secondary Key
Positions
1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard
numeric keypad, enter Function Code 02.
LED (2) turns on.
2. At the Series 600 Keyboard, press the designated key to copy its primary function
into the secondary position.
3. Repeat 2 for next key to be programmed.
4. When completed, press ENTER.
LED (2) turns off.
5. Program the next function code or exit programming mode by entering 99 on Series
600 Keyboard numeric keypad or by swiping the Program Card.
Note: A Sec Op Key or Sec Op Lock Key must be programmed in the primary function
mode in order to use secondary function codes.
03
04
Program Primary
OPOS Keys (03)
and Secondary
OPOS Keys (04)
The keys on the Series 600 Keyboard can be programmed to output unique key codes.
These keys are used with the UTC OPOS keyboard driver. These key codes cannot be
reproduced on a standard keyboard.
1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard
numeric keypad, enter Function Code 03 for primary key or 04 for secondary key
function.
LED (2) turns on.
2. At the Series 600 Keyboard, press the key to be programmed.
LED (2) flashes.
3. On the Series 600 keypad, type the number of the desired OPOS key to be used 01-
50 and then hit the keypad ENTER on the Series 600 Keyboard.
If LED (2) stops flashing, repeat
step 2.
4. Repeat 2 and 3 for next key to be programmed.
5. Exit programming primary/secondary OPOS key functions by pressing 99 on the
Series 600 Keyboard numeric pad.