Ultimate Technology 600 POS Mouse User Manual


 
Series 600 POS Keyboard 48
Table 5. Remote Programming Mode Commands
OP CODE
(HEX)
MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT
B1 BEEPON
Controls pitch and duration of beep. If
valued for pitch (p) and duration (d) omitted
when command activated.
COMMAND: B1pd<CR>
B1 = Op Code
p = pitch in Hz
d = duration in milliseconds
<CR> = terminate command (0D hex)
pitch (Hz) in ASCII
0 = 500 5 = 880
1 = 2000 6 = 1320
2 = 220 7 = 1760
3 = 440 8 = 2640
4 = 660 9 = 3520
duration (mS) in ASCII
0 = 1000 5 = 500
1 = 100 6 = 600
2 = 200 7 = 700
3 = 300 8 = 800
4 = 400 9 = 900
ACKNOWLEDGEMENT: NONE
B2 SENDP
Sends data to selected port: main serial
port, auxiliary serial port, or auxiliary
keyboard port.
COMMAND: B2p...........<CR>
B2 = Op Code
p = data destination port
<CR> = terminate command (0D hex)
p:
0 = serial port 0 (main)
1 = serial port 1 (auxiliary)
2 = keyboard port 0 (main)
3 = keyboard port 1 (auxiliary)
4 = cash drawer 1 fire
5 = cash drawer 2 fire
Where data can be ASCII or CxDx (high and low
nibble hex value) type.
ACKNOWLEDGEMENT: NONE