Series 600 POS Keyboard 22
Table 2. Local Mode Programming Instructions
* = Default Settings
Function Code(s)
Operation Normal Indication Remarks
26 or 36
Comm (RS232)
Main Port 0 (26)
AUX Port 1 (36)
Suffix
1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard
numeric keypad, enter applicable Function Code 26 (Port 0) or 36 (Port 1).
LED (2) flashes.
2. At the auxiliary keyboard, press the desired key or type the desired key sequence.
Note that the maximum number of key codes is limited to 24 – this is equivalent to
approximately 12 key strokes.
If the Series 600 Keyboard beeps and
LED (2) turns off while entering key
codes at the auxiliary keyboard, you
have exceed
ed 24 key codes.
Repeat steps 1 and 2.
3. At the Series 600 Keyboard, press ENTER.
LED (2) turns off.
4. Program the next function code or exit programming mode by entering 99 on Series
600 Keyboard numeric keypad or by swiping the Program Card.