Series 600 POS Keyboard 18
Table 2. Local Mode Programming Instructions
* = Default Settings
Function Code(s)
Operation Normal Indication Remarks
17
18
Magnetic Stripe
Reader (MSR)
Track 1,3
Bad Read (17)
Track 2
Bad Read
Macro (18)
1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard
numeric keypad, enter applicable Function Code 17, or 18.
LED (2) flashes.
2. At
the auxiliary keyboard, press the desired key or type the desired key sequence.
Note that the maximum number of key codes is limited to 24 this is equivalent to
approximately 12 key strokes.
If the Series 600 Keyboard beeps and
LED (2) turns off while entering key
codes at the auxiliary keyboard, you
have exceeded 24 key codes. Repeat
steps 1 and 2.
3. At the Series 600 Keyboard, press ENTER.
LED (2) turns off.
4. Program the next function code or exit programming mode by entering 99 on Series
600 Keyboard numeric keypad or by swiping the Program Card.
19
MSR Send
1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard
numeric keypad, enter Function Code 19.
LED (2) turns on.
2. At the Series 600 Keyboard numeric keypad, enter the applicable number (0 or 1) per
list below to select MSR data from one or both good tracks.
0 = send any good track*
1 = send only if all enabled tracks good
3. Program the next function code or exit programming mode by entering 99 on Series