Ultimate Technology 600 POS Mouse User Manual


 
Series 600 POS Keyboard 47
Table 5. Remote Programming Mode Commands
OP CODE
(HEX)
MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT
B0 LIGHT
Provides on/off control for keyboard light
emitting diode (LED) indicators. PC mode
for NUM and CAP Lock lights is default.
COMMAND: B0Lx<CR>
B0 = Op Code
L = lamp
x = on/off
<CR> = terminate command (0D hex)
L: 0, 1, 2, 3, P in ASCII, where 0 = all. P is
used for PC emulation of NUM and CAPS
Lock
x: PC mode
1 = on; 0 = off
ACKNOWLEDGEMENT: NONE