Search and Close Call Options
Setting the Delay Time
  Srch/CloCall Opt E
Set Delay Time E
This setting determines how long the scanner waits after
a transmission ends before resuming quick search or
Close Call operation. Select your setting, then press E.
Off The scanner resumes immediately when the
transmission ends.
15 secThe scanner waits the set amount of time after
the transmission ends before resuming.
Note: The default setting is 2 seconds.
Setting the Search Frequency Step
  Srch/CloCall Opt E
Set Step E
This setting selects the frequency step used for setting
the channels. Select your setting, then press E.
Auto The step is based on the band (see the table at the
front of the manual)
5.0 kHz, 6.25 kHz, 7.5 kHz, 10.0 kHz, 12.5 kHz, 15.0 kHz,
25.0 kHz, 50.0 kHz, 100.0 kHz The scanner uses the
selected step.
Note: The scanner defaults to Auto.