Xantrex Technology ENET-XFR Power Supply User Manual


 
Operation
3–6 TM-XR9B-01XN
Command Summary
Use these commands to control the operation of the supply. They are
listed here in order of function such as PROGRAMMING, QUERY,
CALIBRATION, and STATUS commands. See “Command Reference”
on page 3–9 for more detailed information about each command and its
use.
Table 3-3
Programming Commands
AUXA Selects the state of the AUXA output signal on the Pin 7 of the
user lines connector.
AUXB Selects the state of the AUXB output signal on the Pin 8 of the
user lines connector.
CLR Initializes the power supply to its Power ON (PON) state.
DLY Sets a programmable time delay which is executed by the supply
before reporting fault conditions after a new output voltage or
current is specified.
GTL Sends the supply to local mode.
FOLD Sets foldback mode for the supply.
HOLD Enables or disables voltage/current setting hold mode for the
supply.
IMAX Sets an upper soft limit on the programmed output current for the
supply.
ISET Sets the output current of the supply in amps (default) or in
milliamps.
LLO Local Lockout. Disables the front panel LOCAL button.
OUT Enables or disables voltage/current output for the supply.
OVSET Sets the over voltage protection trip point for the supply in volts
(default) or in millivolts.
REN Sets remote mode or local mode.
RST Resets the supply to the present voltage and current settings if the
output is disabled by OVP or foldback protection.
TRG Implements programmed voltage and current settings which had
been in hold mode.
VMAX Sets an upper soft limit on the supply’s programmed output
voltage.
VSET Sets the output voltage of the power supply in volts (default) or in
millivolts.