Xantrex Technology ENET-XFR Power Supply User Manual


 
Specifications for XFR 2.8kW with Ethernet/RS-232 Interface Installed
TM-XR9B-01XN A–5
Table A-4
XFR 2.8kW 60 V to 600 V
Program Resolution
Vo ltag e
Current
OVP
9.3mV
1.4mA
9.3mV
15.5mV
0.9mA
15.5mV
23.2mV
0.6mA
23.2mV
46.4mV
0.3mA
46.4mV
92.7mV
0.2mA
92.7mV
Program Accuracy
a
Vo ltag e
Current
OVP
a. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-130 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of
10 volts
150mV
±0.3%
80mA
±0.1%
600mV
150mV
±0.35%
80mA
±0.1%
1.0V
225mV
±0.35%
80mA
±0.1%
1.5V
225mV
±0.35%
75mA
±0.1%
3.0V
300mV
±0.35%
75mA
±0.1%
6V
Readback Resolution
Vo ltag e
Current
9.3mV
1.4mA
15.5mV
0.9mA
23.2mV
0.6mA
46.4mV
0.3mA
92.7mV
0.2mA
Readback Accuracy
a
Vo ltag e
Current
150mV
±0.3%
80mA
±0.1%
150mV
±0.35%
80mA
±0.1%
225mV
±0.35%
80mA
±0.1%
225mV
±0.35%
75mA
±0.1%
300mV
±0.35%
75mA
±0.1%
TM-XR9B-01XN.book Page 5 Monday, April 19, 2004 9:00 AM