Xantrex Technology ENET-XFR Power Supply User Manual


 
Specifications
A–2 TM-XR9B-01XN
Specifications for XFR 1.2kW with Ethernet/RS-232
Interface Installed
Table A-1
XFR 1.2kW 7.5 V to 40 V
Program Resolution
Vo ltag e
Current
OVP
1.2mV
18.3mA
1.2mV
3.1mV
7.1mA
3.1mV
5.1mV
4.7mA
5.1mV
5.4mV
5.4mA
5.4mV
6.2mV
3.6mA
6.2mV
Program Accuracy
a
Vo ltag e
Current
OVP
a. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-60 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of
10 volts.
10mV
±0.12%
500mA
±0.1%
80mV
75mV
±0.12%
250mA
±0.1%
200mV
75mV
±0.12%
165mA
±0.15%
330mV
75mV
±0.3%
200mA
±0.1%
350mV
75mV
±0.3%
140mA
±0.15%
400mV
Readback Resolution
Vo ltag e
Current
1.2mV
18.3mA
3.1mV
7.1mA
5.1mV
4.7mA
5.4mV
5.4mA
6.2mV
3.6mA
Readback Accuracy
a
Vo ltag e
Current
30mV
±0.12%
500mA
±0.1%
75mV
±0.12%
250mA
±0.1%
75mV
±0.2%
165mA
±0.15%
75mV
±0.3%
200mA
±0.1%
75mV
±0.3%
140mA
±0.15%
TM-XR9B-01XN.book Page 2 Monday, April 19, 2004 9:00 AM