Xantrex Technology ENET-XFR Power Supply User Manual


 
Command Summary
TM-XR9B-01XN 3–7
Table 3-4
Query Commands
AUXA? Asks for the state of the set value for the AUXA command
AUXB? Asks for the state of the set value for the AUXB command
CMODE? Asks for the power supply’s calibration mode status.
DLY? Asks for the programmable time delay setting before the supply
reports fault conditions.
ERR? Asks for the most recent remote programming error which
occurred in the supply since the last time the error query
command (ERR?) was used.
FOLD? Asks for the supply’s present foldback setting.
HOLD? Asks for the present hold mode setting.
ID? Asks for the power supply’s model name and master EPROM
version.
IMAX? Asks for the supply’s soft current limit setting.
IOUT? Measures the supply’s actual current output.
ISET? Asks for the supply’s present output current limit setting.
OUT? Asks for the present enabled/disabled status of the supply’s
output.
OVSET? Asks for the supply’s present over voltage protection limit.
REN? Asks for the state of remote enable.
ROM? Asks for the version number of the master and slave EPROMs on
the interface PCB.
VMAX? Asks for the supply’s soft voltage limit setting.
VOUT? Measures the supply’s actual voltage output.
VSET? Asks for the supply’s present output voltage setting.
TM-XR9B-01XN.book Page 7 Monday, April 19, 2004 9:00 AM