ZyXEL Communications B-3000 Network Card User Manual


 
ZyAIR B-3000 User’s Guide
53 Chapter 5 System Screens
Figure 19 Time Setting
The following table describes the labels in this screen.
Table 9 Time Setting
LABEL DESCRIPTION
Time Protocol Select the time service protocol that your time server sends when you turn on
the ZyAIR. Not all time servers support all protocols, so you may have to check
with your ISP/network administrator or use trial and error to find a protocol that
works.
The main difference between them is the format.
Daytime (RFC 867) format is day/month/year/time zone of the server.
Time (RFC 868) format displays a 4-byte integer giving the total number of
seconds since 1970/1/1 at 0:0:0.
The default, NTP (RFC 1305), is similar to Time (RFC 868).
Select None to enter the time and date manually.
Time Server Address Enter the IP address or the URL of your time server. Check with your ISP/
network administrator if you are unsure of this information.
Current Time
(hh:mm:ss)
This field displays the time of your ZyAIR.
Each time you reload this page, the ZyAIR synchronizes the time with the time
server.
New Time (hh:mm:ss) This field displays the last updated time from the time server.
When you select None in the Time Protocol field, enter the new time in this
field and then click Apply.
Current Date (yyyy/
mm/dd)
This field displays the date of your ZyAIR.
Each time you reload this page, the ZyAIR synchronizes the date with the time
server.
New Date (yyyy/mm/
dd)
This field displays the last updated date from the time server.
When you select None in the Time Protocol field, enter the new date in this
field and then click Apply.