3Com 2226-SFP Switch User Manual


 
Monitoring 69
used to detect if a new device is plugged into a
switch port. (Default: Disabled)
Max Count – The maximum number of hosts that
can connect to a port when the Multi-Host
operation mode is selected. (Range: 1-1024;
Default: 5)
Reauthentication Period – Sets the time period after
which a connected client must be re-authenticated.
(Range: 1-65535 seconds; Default: 3600 seconds)
Quiet Period – Sets the time that a switch port waits
after the Max Request Count has been exceeded
before attempting to acquire a new client. (Range:
1-65535 seconds; Default: 60 seconds)
Transmit Period – Sets the time period during an
authentication session that the switch waits before
re-transmitting an EAP packet. (Range: 1-65535;
Default: 30 seconds)
After you have filled in the parameters, click Apply to
save your changes.
Figure 64 802.1X Setup Screen
Monitoring
Using the Web interface, you can display address table
information, set up port mirroring, and perform cable
diagnostics.
The Monitoring menu includes three items:
Address Table
Port Mirroring
Cable Diagnostics
Address Table
The Switch’s address table contains the MAC addresses
learned by monitoring the source address for traffic