3Com Hub 1000 SX Switch User Manual


 
A-12 APPENDIX A: USING THE CONSOLE PORT
Displaying
Hub Status
Hub status includes a matrix of information about the hub ports. In this
matrix, Y indicates yes and n indicates no. (See Table A-3.)
Table A-3 Hub Status Information
Category State Description
Port is enabled Y The port is enabled for linking.
n The port is disabled for linking.
Link state is up Y A link exists between the port and a device.
n No link exists between the port and
a device.
Auto-negotiate link
configuration
Y The port is set for auto-negotiation.
n The port is set for forced link.
Advertise outgoing
flow control
Y The port signals outgoing flow
control capability.
n The port does not signal outgoing flow
control capability.
Advertise incoming
flow control
Y The port signals incoming flow
control capability.
n The port does not signal incoming flow
control capability.
The port does not support incoming
flow control.
Enable outgoing flow control Y or n If auto-negotiation is enabled, the result of
the negotiation between the port and the
linked device is shown. If auto-negotiation
is disabled, the flow control you specify
is shown.
Enable incoming flow control Y or n If auto-negotiation is enabled, the result of
the negotiation between the port and the
linked device is shown. If auto-negotiation
is disabled, the flow control you specify
is shown.
The port does not support incoming
flow control.