APPENDICES SECTION APPENDIX C
138
8E6 TECHNOLOGIES, ENTERPRISE REPORTER ADMINISTRATOR USER GUIDE
Step 4: Rebuild the hard drive
Once the failed hard drive has been replaced, return to the
Hardware Failure Detection screen in the Administrator
console, and click Rebuild to proceed with the rebuild
process.
WARNING: When the RAID array reconstruction process begins,
the message “Enterprise Reporter Functionality Suspended,
Drive Rebuild in Process” displays and the hard drive becomes
inaccessible.
Step 5: Contact Technical Support
Contact Technical Support to order a new replacement hard
drive and for instructions on returning your failed hard drive
to 8e6.
Power supply failure
Step 1: Identify the failed power supply
The administrator of the server is alerted to a power supply
failure on the chassis by an audible alarm and an amber
power supply LED—or an unlit LED—on the front and rear
of the chassis.
NOTE: A steady amber power supply LED also may indicate a
disconnected or loose power supply cord. Verify that the power
supply cord is plugged in completely before removing a power
supply.
WARNING: Be sure the correct failed power supply has been
identified. Removing the wrong power supply will cause the
system to crash.
Step 2: Unplug the power cord
To prevent electrical shock to yourself and damage to the
unit, unplug the power cord from the failed power supply.