Acer G901 Server User Manual


 
Appendix B: System management
164
Platform event management
Events can trigger alerts and other actions by the BMC. The server is
configured with the following set of standard events:
Temperature sensor out of range
Voltage sensor out of range
Fan failure
Chassis intrusion
Power supply fault
BIOS uncorrectable ECC error
BIOS POST error
Processor fault resilient booting (FRB) failure
Fatal nonmaskable interrupt (NMI) from a source other than the
front panel switch
Watchdog timer reset, power down, or power cycle
System restart (reboot)
Alerts can take either of these forms:
Platform event pages
The BMC dials a paging service and sends a predefined paging
string. To use platform event paging (PEP), you must attach an
external modem to the emergency management port (COM2).
BMC LAN alerts
The BMC sends an alert to a predefined destination on the LAN.
You can configure PEP and BMC LAN alerts by using the System Setup
Utility (refer to page 166).
BB!H:11!vh!.!FO/cppl!!Qbhf!275!!Gsjebz-!Kbovbsz!28-!3114!!8;24!QN