Configure and View Status
46 Megabit Modem CRA-C User Manual
7 Days ADSL Performance History. The 7 Day ADSL Performance
History menu displays the ES and UAS counts, and the minimum SNR
margins for the previous 6 days and the current day. The division of the
intervals is based on 12 am midnight as the dividing boundary, and the current
day count is not necessarily equal to the total count for the past 24 hours.
Type
on the ADSL Menu to open the 7 Day ADSL Performance
History menu.
07/02/97 PAIRGAIN TECHNOLOGIES 08:46:07
ATU-C ADSL MEGABIT MODEM TERMINAL 01.01
7 DAY ADSL PERFORMANCE HISTORY
(errored seconds/unavailable seconds/snr)
DOWNSTREAM UPSTREAM
07/02/97 00000/00000/ 13.1 00000/00000/ 7.6
07/01/97 00003/00038/ 13.1 00003/00038/ 7.6
06/30/97 00000/00000/ NA 00000/00000/ NA
06/29/97 00000/00000/ NA 00000/00000/ NA
06/28/97 00000/00000/ NA 00000/00000/ NA
06/27/97 00000/00000/ NA 00000/00000/ NA
06/26/97 00000/00000/ NA 00000/00000/ NA
(C)lear (R)eturn (M)ain
ENTER CHOICE-->
Type to clear all ES and UAS counts, including the equivalent counts in
the remote unit. The minimum SNR for the period is reset to the current SNR.
The 7 Day ADSL Performance History data is lost
when the Megabit Modem CRA-C is turned off.