Chapter 3: Provisioning September 25, 2006
3-4 LTPE-UM-3159-02
Network Screen
The Network screen (Figure 3-2) includes the Login command, Upload menu, and Quit command. The Upload
menu provides the mechanism to upload image files to local or remote line units or to local or remote EMUs for
system management. See “Managing Firmware Through the Upload Menu” on page 3-24 to use this command. The
Quit command provides a logout from the Network screen.
The Network screen also includes the Shelf ID field and the Alarm Status field. The Shelf ID field initially shows Shelf
1 for all shelves in this subnet until the shelf ID is configured for each shelf (see “Set Shelf ID” on page 3-19 for
configuring the Shelf ID). The Alarm Status field shows the active alarm status of each shelf in this multishelf
network.
Figure 3-2. Network Screen
Logging in to the Main menu
To log in to the Main menu:
Main Menu
Use the
Å arrow key to select Main, then press ENTER to display the Main menu screen (Figure 3-3 on page 3-5).
The Main menu screen shows the alarm status for a selected shelf and its DSL cards. It also allows you to log into
the console menu for any card in the shelf and to disable the card’s alarm reporting functions.
Note: The shelf with the > symbol (for example, >Shelf #28 in Figure 3-2) is the local shelf connected to the
management station PC. Other shelves without the > symbol are remote shelves connected to the local
shelf through an Ethernet subnet.
Step Action
1 In the Network screen, select a shelf from 1 to 32 for which you want to view EMU or Line Unit
configuration. Use the
Ç and È arrow keys.
2 Type the letter L (or press ENTER). The Main menu screen for the selected shelf is displayed
(see Figure 3-3 on page 3-5).