ADC EMU-830 Network Card User Manual


 
September 25, 2006 Chapter 3: Provisioning
LTPE-UM-3159-02 3-9
Figure 3-5. Network Parameters Menu
Configure Network Parameters for Multishelf TAO and SNMP
To configure the EMU-830 for Multishelf TAO and
basic SNMP operation (if used) over Ethernet LAN:
Note: The network parameters for each EMU must be configured individually. Once configured, each shelf
reports its status and alarms to the local shelf (the shelf with its EMU connected to the VT100 or PC, either
directly or by modem).
The Ethernet Address parameter is read-only and cannot be changed by the user. When changes are made
to the network parameters, the EMU console will prompt to reset to apply the changes.
Consult your network administrator to obtain the required IP addresses.
Step Action
1 In the Network Parameters menu (Figure 3-5 on page 3-9), the Ethernet Connection type is 10BASE-T.
2 Enter values for the Local IP Address, Local IP Subnet Mask, and, if the management station and EMU
are on different subnets, the Default Gateway IP Address (see Table 3-5 on page 3-10). Ensure that you
use values to place all shelves in the multishelf TAO on the same subnet.
3 In the SNMP Parameters menu (Figure 3-6 on page 3-11), configure at least one trap receiver (ignore this
step if you are not using SNMP). Enter the appropriate values for the Trap (management station) IP
Address and Trap Community string, then toggle the Trap Validation field to Valid (see Table 3-6 on page
3-12).
4 Press ENTER to confirm all network settings.
5 Follow the EMU console prompt to reset the EMU.