ADC EMU-830 Network Card User Manual


 
Chapter 3: Provisioning September 25, 2006
3-8 LTPE-UM-3159-02
Enabling or Disabling Alarm Reporting
To enable or disable alarm reporting for DSL circuits:
Config Menu
In the Main menu screen, use the
Æ arrow key to select Config; then press C to display the items in the Config
menu (Figure 3-4). Provisioning of all shelf parameters is conducted from the Config menu. Each menu item is
described in the paragraphs that follow.
Figure 3-4. Config Menu
Network Parameters Menu
In the Config menu, press N to display the Network Parameters menu (Figure 3-5 on page 3-9). This menu is used
to identify and change the EMU network parameters. The Network Parameters menu options are listed in Table 3-5
on page 3-10.
Step Action
1 In the Main menu screen (Figure 3-3 on page 3-5), type the number 1 in the ENTER SELECTION field
and press ENTER. The Enter line unit number field displays the current line unit selection and Enable or
Disable setting.
2
Enter a line unit number, then use the
Ç arrow key to select the current Enable or Disable setting.
3Use the SPACEBAR to select Enable or Disable.
4 Press ENTER to confirm settings.