ADTRAN MX2800 M13 Network Card User Manual


 
9-14 61200290L1-1G
Section 9, Transaction Language 1 (TL1) MX2800 M13 Multiplexer System Manual
REPT
ALM
EQPT
401
(GENERAL)
MN CTNEQPT NSA NEND Controller Communication
Failure
Check the standby card for proper LED behavior (and replace if
necessary). If no problem is found, call ADTRAN Technical
Support for further troubleshooting details.
402
(CTRL A)
MN CTNEQPT NSA NEND Controller Card Failure Replace the card which reports failure (should be indicated by a
flashing red ACT LED and the AID of the alarm).
403
(CTRL B)
402
(CTRL A)
CR TRMT SA NEND Ds3 Transmit Loss Of Signal Replace the card for which TLOS is reported. Use the aid of the
alarm to identify the card.
403
(CTRL B)
402
(CTRL A)
MN PROTNA NSA NEND Controller Card Removed Check to see if card was removed or reset by on-site personnel.
403
(CTRL B)
404 (PS A) MN PWR NSA NEND Power Supply Failure Replace the failed power supply. Use the aid of the alarm to
identify the card.
405 (PS B)
404 (PS A) MN MISC NSA NEND Power Supply
Communication Failure
Replace the failed power supply. Use the aid of the alarm to
identify the card.
405 (PS B)
Table 9-3. MX2800 Alarm Events (Continued)
AID
Notification
Code
Condition
Type
Service
Affecting
Location Description Recommended Action