ADTRAN MX2800 M13 Network Card User Manual


 
3-20 61200290L1-1G
Section 3, Configuration MX2800 M13 Multiplexer User Manual
Connection Timeout
The MX2800 waits for a connection for the number of seconds entered in this field. Timing begins as soon
as the dial command is issued. This field must be set for greater than 20 seconds.
Pause Between Calls
The MX2800 waits between redial attempts for the number of seconds entered in this field.
Dialout On Trap
This field is used to enable or disable the MX2800’s ability to dial out to report traps. Modem Mode
configured for VT-100 reports error conditions in plain ASCII with the following information:
The Unit ID value programmed in the Equipment Identification portion of the System Management
screen. Refer to System Management on page 3-16.
A trap code indicating the error condition
A text description of the fault
The date and time when the error was logged
When Modem Mode is configured for PPP or SLIP, the MX2800 logs into the PPP/SLIP host and reports
the error conditions to the hosts designated under Trap IP Addresses. Refer to Trap IP Addresses on
page 3-21.
Answer on Ring
This option enables or disables the MX2800’s ability to accept incoming calls. If enabled, incoming calls
are automatically answered by the MX2800, allowing remote performance of management functions.
Modem Mode
This field is used to select the Modem port function for the desired application (VT-100, PPP, or SLIP).
The Modem port, located on the rear panel of the MX2800, provides a telephone line (POTS) for connec-
tion to the internal V.34 modem. This setting applies only if the Management Port is set to Modem. Refer
to Management Port on page 3-17.
Modem Baud Rate
This option is used to set the maximum operating speed in bps of the Modem port:
•1200
•2400
•4800
•9600
19200
38400