ADTRAN MX2800 M13 Network Card User Manual


 
9-22 61200290L1-1G
Section 9, Transaction Language 1 (TL1) MX2800 M13 Multiplexer User Manual
FMT ENUM One of the following:
•CBIT
•M13
Sets framing format to match the format of
the receive signal at the network interface
The framing format s set to CBIT
The framing format is set to M13
LINELEN ENUM One of the following:
•LONG
•SHORT
Identifies Network DS3 line length
LONG - exceeds 50 feet.
SHORT - less than 50 feet.
RMTLPBK ENUM One of the following:
•DISABLE
•EITHER
•FEAC
•CBIT
Indicates whether the unit will respond to
remote loopbacks over FEAC, CBIT,
EITHER, or if remote loopbacks are disabled
DISABLE - do not respond
EITHER - respond over either FEAC or
CBIT
FEAC - respond over FEAC
CBIT - respond over CBIT
SYSCARDARLY Y/N Y or [N] Identifies status of System Controller Card A
alarm relay
Yes (Y) - enables alarm
No (N) - disables alarm
SYSCARDBRLY Y/N Y or [N] Identifies status of System Controller Card B
alarm relay
Yes (Y) - enables alarm
No (N) - disables alarm
SYSCARDCOMMRLY Y/N Y or [N] Identifies status of System Communication
Fail alarm relay
Yes (Y) - enables alarm
No (N) - disables alarm
SYSCARDRLY Y/N Y or [N] Identifies status of System Controller Card
alarm relay
Yes (Y) - enables alarm
No (N) - disables alarm
TMG ENUM One of the following:
•LPD
•INT
Identifies timing supply for the DS3
LPD - loop timed
INT - internal timing source
Table 9-6. TL1 Editing Data Dictionary for DS3 (Continued)