Page 26 © 2002, ADTRAN, Inc. 64200600L1#T-31A
Total Access 600R User Interface Guide (UIG)
SYSTEM CONFIG>SNMP MENU>FDL>FAR END IP ADDRESS
This is the far-end IP address used for FDL management. The FDL is a separate IP network from the
customer data that is configured under the
R
OUTER
menus. The factory default is
0.0.0.0
.
SYSTEM CONFIG>SNMP MENU>FDL>IP NETMASK
This is the subnet mask defining the IP network used for FDL management. The factory default is
0.0.0.0
.
SYSTEM CONFIG>SNMP MENU>FDL>LEARN ADDRESS
When set to
O
N
, the destination address on each received packet is assumed to be the FDL interface
address. A 255.255.255.252 netmask is used, which determines the far-side address as well (since there
can be only two addresses on a subnet with that netmask). When set to
O
FF
, the user must input the IP
address assigned to the FDL interface. Default is
O
N
.
SYSTEM CONFIG>SNMP MENU>FDL>ACCEPT ALL SNMP
When set to
ON
, SNMP gets/sets received over the FDL link are always accepted regardless of the com-
munity table. When set to
OFF
, the community table is searched for valid manager IP addresses and the
SNMP traffic is rejected if a match is not found. Default is
ON
.
SYSTEM CONFIG>MAINT PORT MENU
SYSTEM CONFIG>MAINT PORT MENU>PASSWORD PROTECT
The Total Access 600R’s VT 100
CRAFT
port can be accessed through a RJ-48 connector located on the rear of the
unit. The setup for this port is under this menu.
When
P
ASSWORD
P
ROTECT
is set to
N
O
, the maintenance port is not password protected. When
Y
ES
(def), the 600R will
prompt for a password upon startup.
SYSTEM CONFIG>MAINT PORT MENU>PASSWORD
This is the text string that is used for comparison when password protecting the maintenance port. By default, no pass-
word is entered. You can enter up to 15 characters in this field.
The security level for the maintenance port is always set to 0. This gives full access to all menus.
Passwords are case-sensitive.