Agilent Technologies 66332A Power Supply User Manual


 
4 - Language Dictionary
54
SENSe:WINDow
This command sets the window function that is used in output measurement calculations. The following
functions can be selected:
HANNing
A signal conditioning window that reduces errors in dc and rms measurement
calculations in the presence of periodic signals such as line ripple. It also
reduces jitter when measuring successive pulse waveforms. The Hanning
window multiplies each point in the measurement sample by the function cos
4
.
Do not use the Hanning window when measuring single-shot pulse waveforms.
RECTangular
A window that returns measurement calculations without any signal
conditioning. This window may be used for pulse measurements where the
exact period of the pulse waveform is known and the measurement interval can
be set accordingly using the SENSe:SWEep:TINTerval command.
NOTE: Neither window function alters the instantaneous voltage or current data returned in the
measurement array.
Command Syntax
SENSe:WINDow[:TYPE] <type>
Parameters
HANNing | RECTangular
*RST Value
HANNing
Examples
SENS:WIND RECT
Query Syntax
SENSe:WINDow[:TYPE]?
Returned Parameters
<CRD>