SCPI Conformance Information
SCPI Version
The Agilent Dynamic Measurement DC Source conforms to SCPI Version 1995.0.
SCPI Confirmed Commands
ABOR SENS:SWE:POIN
CAL:DATA SENS:SWE:TINT
CAL:STAT STAT:OPER[:EVEN]?
DISP[:WIND][:STAT] STAT:OPER:COND?
DISP[:WIND]:TEXT[:DATA] STAT:OPER:ENAB
INIT[:IMM]:SEQ | NAME STAT:OPER:NTR
INIT:CONT:SEQ | NAME STAT:OPER:PTR
MEAS | FETC:ARR:CURR[:DC]? STAT:PRES
MEAS | FETC:ARR:VOLT[:DC]? STAT:QUES[:EVEN]?
MEAS | FETC[:SCAL]:CURR[:DC]? STAT:QUES:COND?
MEAS | FETC[:SCAL]:CURR:HIGH? STAT:QUES:ENAB
MEAS | FETC[:SCAL]:CURR:LOW? STAT:QUES:NTR
MEAS | FETC[:SCAL]:CURR:MAX? STAT:QUES:PTR
MEAS | FETC[:SCAL]:CURR:MIN? SYST:ERR?
MEAS | FETC[:SCAL]:VOLT[:DC]? SYST:LANG
MEAS | FETC[:SCAL]:VOLT:HIGH? SYST:VERS?
MEAS | FETC[:SCAL]:VOLT:LOW? TRIG[:SEQ1 | :TRAN][:IMM]
MEAS | FETC[:SCAL]:VOLT:MAX? TRIG[:SEQ1 | :TRAN]:SOUR
MEAS | FETC[:SCAL]:VOLT:MIN? TRIG:SEQ2 | ACQ[:IMM]
OUTP[:STAT] TRIG:SEQ2 | ACQ:SOUR
OUTP:PROT:CLE TRIG:SEQ:DEF
OUTP:PROT:DEL *CLS
[SOUR]:CURR[:LEV][:IMM][:AMPL] *ESE*ESE?*ESR?
[SOUR]:CURR[:LEV]:TRIG[:AMPL] *IDN?
[SOUR]:CURR:PROT:STAT *OPC*OPC?*OPT?
[SOUR]:VOLT[:LEV][:IMM][:AMPL] *PSC*PSC?
[SOUR]:VOLT[:LEV]:TRIG[:AMPL] *RCL*RST
[SOUR]:VOLT:PROT *SAV*SRE*STB?
SENS:CURR[:DC]:RANG[:UPP] *TRG*TST?
SENS:FUNC *WAI
SENS:SWE:OFFS:POIN
Non-SCPI Commands
CAL:CURR[:SOUR][:DC][:POS] OUTP:DFI:SOUR
CAL:CURR[:SOUR][:DC]:NEG OUTP:PON:STAT
CAL:MEAS[:DC]:LOWR OUTP:REL[:STAT]
CAL:MEAS:AC OUTP:REL:POL
CAL:LEV OUTP:RI:MODE
CAL:PASS SENS:CURR:DET
CAL:SAVE [SOUR]:DIG:DATA[:VAL]
CAL:VOLT[:DC] [SOUR]:DIG:FUNC
CAL:VOLT:PROT TRIG:SEQ2 | ACQ:COUN:CURR | :VOLT
DISP[:WIND]:MODE TRIG:SEQ2 | ACQ:HYST:CURR | :VOLT
MEAS | FETC[:SCAL]:CURR:ACDC? TRIG:SEQ2 | ACQ:LEV:CURR | :VOLT
MEAS | FETC[:SCAL]:VOLT:ACDC? TRIG:SEQ2 | ACQ:SLOP:CURR | :VOLT
OUTP:DFI[:STAT]