Agilent Technologies 66332A Power Supply User Manual


 
4 - Language Dictionary
74
TRIGger
When the transient trigger subsystem is initiated, this command generates a trigger signal. The trigger will
then:
1. Initiate a pending level change as specified by CURRent:TRIGger or VOLTage;TRIGger.
2. Clear the WTG bit in the Status Operation Condition register after both transient and acquire trigger
sequences have completed. (WTG is the logical-or of both transient and acquire sequences.)
3. If INITiate:CONTinuous ON has been programmed, the trigger subsystem is immediately re-enabled
for subsequent triggers. As soon as it is cleared, the WTG bit is again set to 1.
Command Syntax
TRIGger[:SEQuence1][:IMMediate]
TRIGger[:TRANsient][:IMMediate]
Parameters
None
Examples
TRIG TRIG:IMM
Related Commands
ABOR CURR:TRIG INIT *TRG VOLT:TRIG
TRIGger:SOURce
This command is included for completeness. It selects the trigger source for transient triggers. Since BUS
is the only trigger source for transient triggers, this command does not need to be used.
BUS
GPIB device, *TRG, or <GET> (Group Execute Trigger)
Command Syntax
TRIGger[:SEQuence1]:SOURce<source>
TRIGger[:TRANsient]:SOURce<source>
Parameters
BUS
*RST Value
BUS
Examples
TRIG:SOUR BUS
Query Syntax
TRIGger[:SEQuence1]:SOURce?
TRIGger[:TRANsient]:SOURce?
Returned Parameters
<CRD>
TRIGger:SEQuence2
TRIGger:ACQuire
Agilent 66312A, 66332A Only
When the trigger subsystem is initiated, these commands generate a measurement trigger signal. The
measurement trigger causes the dc source to measure the output voltage and current and store the
results in a buffer.
.
Command Syntax
TRIGger:SEQuence2[:IMMediate]
TRIGger:ACQuire:[:IMMediate]
Parameters
None
Examples
TRIG:SEQ2 TRIG:ACQ
Related Commands
TRIG:SOUR TRIG:SEQ2:DEF TRIG:SEQ2:COUN
TRIG:SEQ2:LEV:VOLT TRIG:SEQ2:SLOP:CURR