Allied Telesis C613-16164-00 REV E Network Card User Manual


 
VCStack and VRF-lite
Page 72 | Configure VRF-lite
Virtual Chassis ID
Also, the optional command stack virtual-chassis-id <value> specifies the VCS virtual chassis
ID.
If not configured, the stack will automatically select a virtual-chassis-id from a number within
the assigned range 0-4095. The ID selected will determine which virtual MAC address the
stack will automatically use. The MAC address assigned to a stack must be unique within its
network.
For more information about VCStack, refer to http://www.alliedtelesis.com/media/fount/
how_to_note_alliedware_plus/overview_aw_plus__stacking_REVD.pdf.
X610 VCStack configuration
!
hostname DUTA
!
stack virtual-chassis-id 2034
!
ip vrf violet 7
rd 100:7
!
ip vrf grey 8
rd 100:8
!
switch 1 provision x610-48
switch 2 provision x610-48
!
vlan database
vlan 10-11,14-15 state enable
!
interface port1.0.1
switchport access vlan 14
!
interface port1.0.11
switchport access vlan 11
!
interface port1.0.14
switchport access vlan 14
!
interface port2.0.1
switchport access vlan 15
!
interface port2.0.10
switchport access vlan 10
!
interface port2.0.15
switchport access vlan 15
!
interface lo7
ip address 7.7.7.1/32
!
interface lo8
ip address 8.8.8.1/32
!
interface vlan10
ip vrf forwarding violet
ip address 10.10.10.1/24
!
interface vlan11
ip vrf forwarding grey