Asante Technologies 1012 Network Router User Manual


 
Page 2-22
Chapter 2 — Connecting to the Network
Table 2-2 lists the factory default settings.
*
Communication with a terminal is fixed at 9600 bps.
Table 2-2 AsantéHub 1012 Factory Default Settings
Default To Modify
All RJ45/RJ21 ports have Link Integrity testing
enabled. Jumper JP8 is set OUT to enable
Link Integrity testing on the 3-in-1 Uplink
If you are using AsantéHub with a pre-10BaseT device,
disable Link Integrity. (You will not be able to obtain link
integrity status from disabled ports.)
To disable Link Integrity testing over the 3-in-1 Uplink
set JP8 IN.
To disable Link Integrity testing over device links, use
the Port Control window in AsantéView.
Primary link selection follows autoselection
sequence. Jumper JP7 is set OUT.
To force primary link selection to AUI, set jumper JP7
IN.
All front panel ports (RJ45) are hardware-con-
figured IN and cannot be modified.
To connect two hubs using front panel ports, use a
crossover RJ45 cable (see Appendix C for pinouts).
Port Control:
Link Test enabled
Jabber detection enabled
Polarity Correction enabled
Receive Threshold not reduced
Reconfigure using Port Control window in AsantéView.
Bridge/Hub Port (AMS Link): 9600 bps, 8 data
bits, 1 stop bit, no parity
Cannot be modified.
Local Management Port (RS-232): 9600 bps, 8
data bits, 1 stop bit, no parity. (Communica-
tion rate between hub and PC or modem on
RS-232 port.)
*
Configure using VT100 or PC/Macintosh running VT100
emulation software.
Node Age time: 60 seconds. (Storage period
for hub statistics.)
Configure in AsantéView.
SYS contact: none Configure in AsantéView or with Local Management
SNMP Read Community string: public Configure in AsantéView or with Local Management
SNMP Write Community String: private Configure in AsantéView or with Local Management
Modem Dial string: none Configure in AsantéView or with Local Management
Default
Settings