Asante Technologies 1012 Network Router User Manual


 
Page 3-36
Chapter 3 — AsantéBridge 1012 Local Management
You can reset the AsantéBridge 1012 in three different ways:
Cycle the power. This resets both the bridge and hub
portions of the device. The repeater is not affected.
Push the Reset button on the front panel. This resets
both hub and bridge.
Send the Reset system command from the Configura-
tion Menu
. This resets both the bridge and the hub.
Figure 3-21 Resetting the Bridge
1
Use the arrow keys to select the Reset system command.
2
Press return to reset the bridge.
Confirmation is required. The command executes only
after you have confirmed your choice.
Your display will begin to cycle through the bridge power-
on diagnostics and return to the
Local Management
Menu
.
3
Enter control-z to return to the Local Management Menu.
Remember that a reset:
Resets the bridge and hub statistics counters to zero
Erases any packets in bridge and hub memory at the
time of the reset
Prevents the bridge from forwarding or filtering data
flow until the power-on diagnostics have run to comple-
tion and the bridge has completed reconfiguring
Erases dynamic forwarding addresses
Resetting the Bridge